Differential prober

Oversigsskema​

Model TT-SI 9001​ - 1:10 og 1:100

  • Bandwidth DC to 25 MHz (-3dB)
  • Attenuation Ratio x10 / x100
  • DC Accuracy ±2 %
  • Input Impedance 4 MΩ, 5.5 pF
  • Rise Time 14 ns
  • Measurement Category CAT III
  • Max. Amplitude ±7 V (into 2 kΩ load)
  • Offset <±5 mV
  • Noise (typical) 0.7 mVrms
  • Source Impedance (typical) 1 Ω @ 1 kHz, 8 Ω @ 1 MHz
  • CMRR (typical) -86 dB @ 50 Hz, -66 dB @ 20 kHz
  • Input Voltage
​Differential Mode x10 ±70 V (DC + peak AC)
or 70 Vrms
x100 ±700 V (DC + peak AC)
or 700 Vrms
  • Input Voltage
Common Mode x10 ±700 V (DC + peak AC)
or 700 Vrms
x100 ±700 V (DC + peak AC)
or 700 Vrms
  • Input Voltage
Absolute max. Voltage x10 ±1400 V (DC + peak AC)
​or 1000 Vrms
x100 ±1400 V (DC + peak AC)
or 1000 Vrms
  • Power requirements 4x AA Cells or Mains Adaptor
6 VDC / 60 mA
or regulated 9 VDC / 40 mA
  • Dimensions (L x W x H) 170 mm x 63 mm x 21 mm
  • Cable BNC Cable 95 cm
  • Input Leads 45 cm
  • Weight 400 g (Probe and PVC-Jacket included)​

Kontakt:

Niels Brix

T: 43963010

E: nb@metronic.dk

Model TT-SI 9002 - 1:20 og 1:200

  • Bandwidth DC to 25 MHz (-3dB)
  • Attenuation Ratio x20 / x200
  • DC Accuracy ±2 %
  • Input Impedance 4 MΩ, 5.5 pF
  • Rise Time 14 ns
  • Measurement Category CAT III
  • Max. Amplitude ±7 V (into 2 kΩ load)
  • Offset <±5 mV
  • Noise (typical) 0.7 mVrms
  • Source Impedance (typical) 1 Ω @ 1 kHz, 8 Ω @ 1 MHz
  • CMRR (typical) -86 dB @ 50 Hz, -66 dB @ 20 kHz
  • Input Voltage
​Differential Mode x20 ±140 V (DC + peak AC)
or 140 Vrms
x200 ±1400 V (DC + peak AC)
or 1000 Vrms
  • Input Voltage
Common Mode x20 ±1400 V (DC + peak AC)
or 1000 Vrms
x200 ±1400 V (DC + peak AC)
or 1000 Vrms
  • Input Voltage
Absolute max. Voltage x20 ±1400 V (DC + peak AC)
or 1000 Vrms
x200 ±1400 V (DC + peak AC)
​or 1000 Vrms
  • Power requirements 4x AA Cells or Mains Adaptor
6 VDC / 60 mA
or regulated 9 VDC / 40 mA
  • Dimensions (L x W x H) 170 mm x 63 mm x 21 mm
  • Cable BNC Cable 95 cm
  • Input Leads 45 cm
  • Weight 400 g (Probe and PVC-Jacket included)​​

Kontakt:

Niels Brix

T: 43963010

E: nb@metronic.dk

Model TT-SI 9071​ - 1:10 og 1:100

  • Bandwidth DC to 70 MHz (-3 dB)
  • Attenuation Ratio x10 / x100
  • DC Accuracy ±1 %
  • Input Impedance 4 MΩ, 5.5 pF each side to ground
  • Rise Time 5 ns
  • Measurement Category CAT III
  • Max. Amplitude ±7 V (into < 5 kΩ load)
  • Offset <±5 mV
  • Noise (typical) 2 mVrms
  • Source Impedance (typical) 50 Ω (for using 1 MΩ
  • input system oscilloscope)
  • CMRR (typical) -80 dB @ 50 Hz, -60 dB @ 20 kHz
  • -46 dB @ 1 MHz, -40 dB @ 10 MHz
  • Input Voltage
Differential Mode x10 ±70 V (DC + peak AC)
or 70 Vrms
x100 ±700 V (DC + peak AC)
or 700 Vrms
  • Input Voltage
Common Mode x10 ±700 V (DC + peak AC)
or 700 Vrms
x100 ±700 V (DC + peak AC)
or 700 Vrms
  • Input Voltage
Absolute max. Voltage x10 ±1400 V (DC + peak AC)
or 1000 Vrms
​x100 ±1400 V (DC + peak AC
or 1000 Vrms
  • Power requirements 4x AA Cells or Mains Adaptor
6 VDC / 100 mA
  • or regulated9 VDC / 70 mA
  • Dimensions (L x W x H) 170 mm x 63 mm x 21 mm
  • Cable BNC Cable 95 cm
  • Input Leads 45 cm
  • Weight 400 g (Probe and PVC-Jacket included)​​

Kontakt:

Niels Brix

T: 43963010

E: nb@metronic.dk

Model TT-SI 9101 | 1:10 / 1:100

  • Bandwidth 100 MHz
  • Attenuation Ratio x10 / x100
  • DC-Accuracy ±2 %
  • Input Impedance 4 MΩ, 7 pF
  • Rise Time 3.5 ns
  • Measurement Category CAT III
  • Max. Amplitude ±7 V (into 50 kW load)
  • Offset <±5 mV
  • Noise (typical) 0.9 mVrms
  • Source Impedance 50 W
  • CMRR (typical) -85 dB @ 50 Hz, -50 dB @ 1 MHz
  • Input Voltage
Differential Mode x10 ±70 V (DC + peak AC)
or 70 Vrms
x100 ±700 V (DC + peak AC)
or 700 Vrms
  • Input Voltage
Common Mode x10 ±700 V (DC + peak AC)
or 700 Vrms
x100 ±700 V (DC + peak AC)
or 700 Vrms
  • Input Voltage
Absolute max. Voltage x10 ±1400 V (DC + peak AC)
or 1000 Vrms
x100 ±1400 V (DC + peak AC)
or 1000 Vrms
  • Dimensions (L x W x H) 202 mm x 83 mm x 38 mm
  • Weight 500 g
  • Accessories Hardcase and Power Supply are included

​​Kontakt:

Niels Brix

T: 43963010

E: nb@metronic.dk

Model TT-SI 9110 | 1:100 / 1:1000

  • Bandwidth 100 MHz
  • Attenuation Ratio x100 / x1000
  • DC-Accuracy ±2 %
  • Input Impedance 4 MΩ, 7 pF
  • Rise Time 3.5 ns
  • Measurement Category CAT III
  • Max. Amplitude ±1.4 V (into 50kΩ load)
  • Offset <±5 mV
  • Noise (typical) 0.6 mVrms
  • Source Impedance (typical) 50 Ω
  • CMRR (typical) -80 dB @ 60 Hz, -50 dB @ 1 MHz
  • Input Voltage
Differential Mode x100 ±140 V (DC + peak AC)
or 140 Vrms
x1000 ±1400 V (DC + peak AC)
or 1000 Vrms
  • Input Voltage
Common Mode x100 ±1400 V (DC + peak AC)
or 1000 Vrms
x1000 ±1400 V (DC + peak AC)
or 1000 Vrms
  • Input Voltage
Absolute max. Voltage x100 ±1400 V (DC + peak AC)
or 1000 Vrms
x1000 ±1400 V (DC + peak AC)
or 1000 Vrms
  • Power Requirements 4x AA Cells or Mains Adaptor
6 VDC / 200 mA
or 9 VDC / 120 mA
  • Dimensions (L x W x H) 207 mm x 83 mm x 38 mm
  • Cable BNC Cable 90 cm
  • Input Leads 30 cm
  • Weight 500 g
  • Accessories We recommend Power Supply TT-SI NT

​​Kontakt:

Niels Brix

T: 43963010

E: nb@metronic.dk

​Model TT-SI 9010 | 1:100 / 1:1000

  • Bandwidth 70 MHz
  • Attenuation Ratio x100 / x1000
  • DC-Accuracy ±2 %
  • Input Impedance 10 MΩ, 10 pF
  • Rise Time 5 ns
  • Measurement Category CAT I
  • Max. Amplitude ±1.4 V (into 50kΩ load)
  • Offset <±5 mV
  • Noise (typical) 0.9 mVrms
  • Source Impedance (typical) 50 Ω
  • CMRR (typical) -80 dB @ 50 Hz, -60 dB @ 1 MHz
  • Input Voltage
Differential Mode x100 ±700 V (DC + peak AC)
or 700 Vrms
x1000 ±7000 V (DC + peak AC)
or 2500 Vrms
  • Input Voltage
Common Mode x100 ±7000 V (DC + peak AC)
or 2500 Vrms
x1000 ±7000 V (DC + peak AC)
or 2500 Vrms
  • Input Voltage
Absolute max. Voltage x100 ±7000 V (DC + peak AC)
or 2500 Vrms
x1000 ±7000 V (DC + peak AC)
or 5000 Vrms
  • Power requirements 4x AA Cells or Mains Adaptor
6 VDC / 200 mA
or reguliert 9 VDC / 120 mA
  • Dimensions (L x W x H) 202 mm x 83 mm x 38 mm
  • Cable BNC Cable 90 cm
  • Input Leads 60 cm
  • Weight 500 g (4 Cells included)
  • Accessories We recommend Power Supply TT-SI NT

Kontakt:

Niels Brix

T: 43963010

E: nb@metronic.dk

Model TT-SI 9010A | 1:100 / 1:1000

  • Bandwidth 70 MHz
  • Attenuation Ratio x100 / x1000
  • DC-Accuracy ±2 %
  • Input Impedance 50 MΩ, 10 pF
  • Rise Time 5 ns
  • Measurement Category CAT III
  • Max. Amplitude ±1.4 V (into 50kΩ load)
  • Offset <±5 mV
  • Noise (typical) 0.9 mVrms
  • Source Impedance (typical) 50 Ω
  • CMRR (typical) -80 dB @ 50 Hz, -60 dB @ 20 kHz
  • Input Voltage
Differential Mode x100 ±700 V (DC + peak AC)
or 500 Vrms
x1000 ±7000 V (DC + peak AC)
or 5000 Vrms
  • Input Voltage
Common Mode x100 ±7000 V (DC + peak AC)
or 5000 Vrms
x1000 ±7000 V (DC + peak AC)
or 5000 Vrms
  • Input Voltage
Absolute max. Voltage x100 ±7000 V (DC + peak AC)
or 5000 Vrms
x1000 ±7000 V (DC + peak AC)
or 5000 Vrms
  • Power requirements 4x AA Cells or Mains Adaptor
6 VDC / 200 mA
or regulated 9 VDC / 120 mA
  • Dimensions (L x W x H) 202 mm x 83 mm x 38 mm
  • Cable BNC Cable 90 cm
  • Input Leads 60 cm
  • Weight 500 g (4 Cells included)
  • Accessories We recommend Power Supply TT-SI NT​

Kontakt:

Niels Brix

T: 43963010

E: nb@metronic.dk

Model TT-SI 50 | 1:10

  • Bandwidth 50 MHz
  • Attenuation Ratio x10
  • DC-Accuracy ±1 %
  • Input Impedance 1.6 MΩ, 7 pF
  • Measurement Category CAT I
  • Input Voltage
Differential Mode ±70 V (DC + peak AC) or 70 Vrms
  • Input Voltage
Common Mode ±700 V (DC + peak AC) or 600 Vrms
  • Input Voltage
Absolute max. Voltage ±700 V (DC + peak AC) or 600 Vrms
  • Power requirements Battery pack (4x AA Cells)
or Main Adaptors 6 VDC / 90 mA
or regulated 9 VDC / 70 mA
  • Dimensions (L x W x H) 111 mm x 22 mm x 14 mm
  • Cable BNC Cable 125 cm
  • Input Leads 50 cm
  • Weight 300 g Hardcase included

​​Kontakt:

Niels Brix

T: 43963010

E: nb@metronic.dk

Model TT-SI 51 | 1:100

  • Bandwidth 50 MHz
  • Attenuation Ratio x100
  • DC-Accuracy ±1 %
  • Input Impedance 4 MΩ, 7 pF
  • Measurement Category CAT II
  • Input Voltage
Differential Mode ±700 V (DC + peak AC) or 600 Vrms
  • Input Voltage
Common Mode ±1400 V (DC + peak AC) or 600 Vrms
  • Input Voltage
Absolute max. Voltage ±1400 V (DC + peak AC) or 600 Vrms
  • Power requirements Battery pack (4x AA Cells)
or Main Adaptors
6 VDC / 90 mA
or regulated 9 VDC / 70 mA
  • Dimensions (L x W x H) 111 mm x 22 mm x 14 mm
  • Cable BNC Cable 125 cm
  • Input Leads 50 cm
  • Weight 300 g Hardcase included​

Kontakt:

Niels Brix

T: 43963010

E: nb@metronic.dk

Model TT-SI 200 | 1:10

  • Bandwidth 200 MHz
  • Attenuation Ratio x10
  • DC-Accuracy ±1 %
  • Input Impedance 500 kW, 7 pF
  • Measurement Category CAT I
  • Rise Time 1.75 ns
  • Max. Amplitude ±2 V (into 50 W load)
  • Offset <±2 mV
  • Noise (typical) 0.3 mVrms
  • Source Impedance (typical) 50 W
  • CMRR (typical) -80 dB @ 100 Hz, -50 dB @ 10 MHz
  • Input Voltage
Differential Mode ±20 V (DC + peak AC or rms)
  • Input Voltage
Common Mode ±60 V (DC + peak AC or rms)
  • Input Voltage
Absolute max. Voltage ±60 V (DC + peak AC or rms)
  • Power requirements Main Adaptors 12 VDC / 50 mA
  • Dimensions (L x W x H) 111 mm x 22 mm x 14 mm
  • Cable BNC Cable 120 cm
  • Weight 130 g

Kontakt:

Niels Brix

T: 43963010

E: nb@metronic.dk

​​

HV prober

​Model TT-HVP 08 | 1000:1

  • Attenuation Ratio x1000
  • Accuracy
VDC ±2 % [+5 kV]
±3 % [+5 kV-8 kV]
VAC ±3 % @ 1 kHz
  • Input Impedance 100 MΩ, 3 pF
  • Bandwidth 40 MHz (-3 dB)
  • Rise Time 9 ns
  • Cable Length 2,0 m
  • Compensation Range 10..30 pF
  • Max. Input Voltage DC 8 kV, AC 6 kVrms, PEAK 16 kV
  • Dimensions (L x W x H) 220 mm x 50 mm x 50 mm
  • IEC1010 CAT I Pollution Degree 2

Kontakt:

Niels Brix

T: 43963010

E: nb@metronic.dk

Model TT-HVP 15HF | 1000:1

  • Attenuation Ratio x1000
  • Accuracy
VDC ±6 %
VAC ±6 % @ 1 kHz
  • Input Impedance 100 MΩ, 1 pF
  • Bandwidth 50 MHz (-3 dB)
  • Rise Time 7 ns
  • Cable Length 2,0 m
  • Compensation Range 15..30 pF
  • Max. Input Voltage DC 15 kV, AC 10 kVrms, PEAK 30 kV
  • Dimensions (L x W x H) 350 mm x 75 mm x 75 mm
  • IEC1010 CAT I Pollution Degree 2​

Kontakt:

Niels Brix

T: 43963010

E: nb@metronic.dk

Model TT-HVP 2739 | 1000:1

  • Attenuation Ratio x1000
  • Accuracy
VDC ±3 %
VAC ±6 % @ 1 kHz
  • Input Impedance 900 MΩ, 1 pF
  • Bandwidth DC ~220 MHz
  • Rise Time 1,6 ns
  • Cable Length 2,0 m
  • Compensation Range 15..35 pF
  • Max. Input Voltage DC+AC peak 39 kV, AC 27 kVrms
  • Dimensions (L x W x H) 320 mm x 80 mm x 80 mm
  • IEC1010 CAT I Pollution Degree 2

​​Kontakt:

Niels Brix

T: 43963010

E: nb@metronic.dk

​HF prober

Model TT-AF 1200 | 1:10

  • Bandwidth DC to 1.2 GHz (-3 dB)
  • Attenuation Ratio x10
  • Accuracy ±2 %
  • Input Impedance 1 MΩ, 3 pF
  • Rise Time 291 ps
  • Input Voltage
±15 V (DC+peak AC)
±40 V (DC+peak AC)
  • absolute maximum voltage
Output Voltage - Swing ±1,5 V (into 50 Ω load)
Output Voltage - Offset (typical) <±5 mV
Adjustable output offset range -28 mV to +28 mV
Output Voltage - Noise (typical) 0,9 mVrms
  • Output Impedance (typical) 50 Ω (for using 50 Ω input system oscilloscope)
  • Ambient Operating Temperature -10 °C to 40 °C
  • Ambient Storage Temperature -30 °C to 70 °C
  • Ambient Operating Humidity 0 % to 85 % humidity
  • Ambient Storage Humidity 0 % to 85 % humidity
  • Power Requirements
Standard 9 V battery or mains adapter
5 VDC / 200 mA or 9 VDC / 150 mA
  • Power Requirements
Optional power leads (USB, Probus® or Lemo®)
  • Length of BNC Cable 120 cm
  • Weight 200 g
  • Dimensions (L x W x H) 83 mm x 19 mm x 14 mm

​​Kontakt:

Niels Brix

T: 43963010

E: nb@metronic.dk

Strøm prober​

Oversigtsskema​

Model TT-CC 220

  • Measurement Ranges 100 mV/A - 10 mV/A
  • Current 10 A - 100 A
  • DC Measurement Accuracy
  • ±3% ±50 mA @ 100 mV/A
  • ±4% ±50 mA @ 10 mV/A
  • ±15% max @ 10 mV/A
  • Bandwidth DC - 300 kHz
  • Rise and Fall Time 1.2 µs
  • Max. Working Voltage
600 VAC RMS CAT II /
300 VAC RMS CAT III
  • Max. Floating Voltage
600 VAC RMS CAT II /
300 VAC RMS CAT III
  • Battery-Typ 9 V Alkaline (NEDA 1604, IEC 6LR61)
  • Battery Life 8 h
  • Operating Temperature 0 bis 50 °C
  • Storage Temperature -20 bis 80 °C
  • Max. Operating Humidity
0 bis 40 °C, 95 % humidity
40 bis 50 °C, 45 % humidity
  • Pollution Degree 2
  • Maximum Conductor 11 mm
  • Dimensions (L x B x H) 265 mm x 80 mm x 36 mm
  • Weight 260 g
  • Accessories Hardcase and Power Supply included​

Kontakt:

Niels Brix

T: 43963010

E: nb@metronic.dk

Model TT-CC 550

  • Measurement Ranges 200 mV/A - 20 mV/A
  • Current 5 A - 50 A
  • DC Measurement Accuracy ±3% ±30 mA @ 200 mV/A
  • ±4% ±300 mA @ 20 mV/A
  • ±15% @ 200 mV/A
  • Bandwidth DC - 500 kHz
  • Rise and Fall Time 0.7 µs
  • Max. Working Voltage
600 VAC RMS CAT II /
300 VAC RMS CAT III
  • Max. Floating Voltage
600 VAC RMS CAT II /
300 VAC RMS CAT III
  • Battery-Typ 9 V Alkaline (NEDA 1604, IEC 6LR61)
  • Battery Life 8 h
  • Operating Temperature 0 bis 50 °C
  • Storage Temperature -20 bis 80 °C
  • Max. Operating Humidity
0 bis 40 °C, 95 % humidity
40 bis 50 °C, 45 % humidity
  • Pollution Degree 2
  • Maximum Conductor 11 mm
  • Dimensions (L x B x H) 265 mm x 80 mm x 36 mm
  • Weight 260 g
  • Accessories Hardcase and Power Supply included​

Kontakt:

Niels Brix

T: 43963010

E: nb@metronic.dk

Model TT-CC 770

  • Measurement Ranges 500 mV/A - 50 mV/A
  • Current 7 A - 70 A
  • DC Measurement Accuracy
  • ±3% ±20 mA @ 500 mV/A
  • ±4% ±200 mA @ 50 mV/A
  • ±15% @ 50 mV/A
  • Bandwidth DC - 1 MHz
  • Rise and Fall Time 0.35 µs
  • Max. Working Voltage
600 VAC RMS CAT II /
300 VAC RMS CAT III
  • Max. Floating Voltage
600 VAC RMS CAT II /
300 VAC RMS CAT III
  • Battery-Typ 9 V Alkaline (NEDA 1604, IEC 6LR61)
  • Battery Life 6 h
  • Operating Temperature 0 bis 50 °C
  • Storage Temperature -20 bis 80 °C
  • Max. Operating Humidity
0 bis 40 °C, 95 % humidity
40 bis 50 °C, 45 % humidity
  • Pollution Degree 2
  • Maximum Conductor 10.3 mm
  • Dimensions (L x B x H) 262 mm x 80 mm x 36 mm
  • Weight 310 g
  • Accessories Hardcase and Power Supply included

​​Kontakt:

Niels Brix

T: 43963010

E: nb@metronic.dk

​Model TT-CC 990

  • Measurement Ranges 1 V/A - 100 mV/A
  • Current 4 A - 40 A
  • DC Measurement Accuracy
  • ±3% ±10 mA @ 1 V/A
  • ±4% ±100 mA @ 100 mV/A
  • Bandwidth DC - 1.5 MHz
  • Rise and Fall Time 0.23 µs
  • Max. Working Voltage
600 VAC RMS CAT II /
300 VAC RMS CAT III
  • Max. Floating Voltage
600 VAC RMS CAT II /
300 VAC RMS CAT III
  • Battery-Typ 9 V Alkaline (NEDA 1604, IEC 6LR61)
  • Battery Life 4 h
  • Operating Temperature 0 bis 50 °C
  • Storage Temperature -20 bis 80 °C
  • Max. Operating Humidity
0 bis 40 °C, 95 % humidity
40 bis 50 °C, 45 % humidity
  • Pollution Degree 2
  • Maximum Conductor 10.3 mm
  • Dimensions (L x B x H) 262 mm x 80 mm x 36 mm
  • Weight 310 g
  • Accessories Hardcase and Power Supply included

Kontakt:

Niels Brix

T: 43963010

E: nb@metronic.dk

Metronic - Marielundvej 30, 2730 Herlev - Tlf.: 43 96 30 10 - Mail: info@metronic.dk - CVR: 33866690​